Trial Number 11

(Client Number 153, Project Number 1)

Trial Purpose: Laboratory evaluations of alternative cleaning products

Date Run: 07/16/99

Experiment Procedure:
Two products were diluted to 5% and heated to 130 F. Copper coupons were coated with a coating and an ink.

Trial Results
The black dye may be pulling off some copper during immersion.  These two products don't react with copper.  No signs of corrosion were detected
visually.


Success Rating
Lab evaluation based on vendor data.

Conclusion
Mostly successful in removing the ink. Some mixed results on the coating.