CleanerSolutions Database
Toxics Use Reduction Institute · Surface Solutions Laboratory
 
Toxics Use Reduction Institute




Surface Solutions Laboratory

Trial Report



Trial Number 154

(Client Number 153, Project Number 1)

Trial Purpose: Laboratory evaluations of alternative cleaning products

Date Run: 01/18/02

Experiment Procedure:
Degasing :Degasing the solution by keeping solutions in ultrasonic crest for 5 min at 120 F.
Cleaning : Ultrasonic for 2 min. at 120 F.
Rinsing : 1/2 min. manual with water at 120 F.
Contaminant: ITW, Dykem Corp, Ink, Steel Blue - DX - 100

Trial Results


Success Rating
Lab evaluation based on vendor data.

Conclusion
Only Perfect way 147 was found to be effective with 104.00% removal on average. This differs from trial 147, where the same ultrasonics and cleaners were used (except for Natural Blue was used in Trial 147) after 5 minute immersion cleaning in trial 145.