CleanerSolutions Database
Toxics Use Reduction Institute · Surface Solutions Laboratory
 
Toxics Use Reduction Institute




Surface Solutions Laboratory

Trial Report



Trial Number 241

(Client Number 153, Project Number 1)

Trial Purpose: Laboratory evaluations of alternative cleaning products

Date Run: 03/28/03

Experiment Procedure:
Cleaning: 5 min Immersion cleaning with stirbar agitation @ 120 F
Rinsing: 1/2 min, manual, in 102 F water (tap)
Drying : 30 seconds air blow off, 68 F
Contaminant: Ferrocote 5815 LVO

Trial Results


Success Rating
Lab evaluation based on vendor data.

Conclusion
After cleaning, wiping was performed to see if efficiencies would increase significantly. Trial 255 shows these results