Trial Report



Trial Number 260

(Client Number 153, Project Number 1)

Trial Purpose: Laboratory evaluations of alternative cleaning products

Date Run: 09/09/03

Experiment Procedure:
Eight products were used at full strength, heated to 120 F on a hot plate. Twenty four preweighed coupons were coated with Ashland Chemical Aroset PS 8078 adhesive (141-78-6, 142-82-5, 67-63-0) and allowed to dry overnight and reweighed.
Three coupons were cleaned in each solution for 5 minutes using stir-bar-agitation, rinsed in a tap water bath for 15 seconds at 120 F and dried using air blow off for 30 seconds at 68 F. Coupons were allowes to dry overnight and then reweighed a final time. Efficiencies were calculated.

Note: Bio T Foam Plus was sprayed onto coupons at room temperature and allowed to sit for 5 minutes. The cleaner was then wiped clean.

Trial Results
Only one product had postive removal of this adhesive.


Success Rating
Lab evaluation based on vendor data.

Conclusion
Ecolink VG 151 may work with longer cleaning time, or more wiping.