CleanerSolutions Database
Toxics Use Reduction Institute · Surface Solutions Laboratory
 
Toxics Use Reduction Institute




Surface Solutions Laboratory

Trial Report



Trial Number 286

(Client Number 153, Project Number 1)

Trial Purpose: Laboratory evaluations of alternative cleaning products

Date Run: 10/28/03

Experiment Procedure:
03-AL-FL-15-8-287 Three products were used at full strength at room temperature and five products were heated to 130 F on a hot plate. Twenty four preweighed coupons were coated with Flux Alpha 615 RMA (67-63-2, 8052-41-3, 8050-09-7) and allowed to dry for a half an hour and reweighed. Three coupons were cleaned in each solution for 5 minutes using stir-bar-agitation, rinsed in a tap water bath for 15 seconds at 120 F and dried using air blow off for 30 seconds at 68 F. Coupons were allowed to dry for a half an hour and then reweighed a final time. Effeciencies were calculated.

Trial Results


Success Rating
Lab evaluation based on vendor data.

Conclusion
All products that were used at a concentration of 5% and one at a concentration of 100% were effective at an efficiency rate of over 98%