CleanerSolutions Database
Toxics Use Reduction Institute · Surface Solutions Laboratory
 
Toxics Use Reduction Institute




Surface Solutions Laboratory

Trial Report



Trial Number 318

(Client Number 153, Project Number 1)

Trial Purpose: Laboratory evaluations of alternative cleaning products

Date Run: 03/05/04

Experiment Procedure:
04-AL- CO-15-4-339 three products were used at full strength and one product was heated to 130 F on a hot plate. Twelve preweighed coupons were coated with PPG Industries Hi Gord 1035 and allowed to dry for a half an hour and reweighed. Three coupons were cleaned in each solution for 5 minutes using stir-bar-agitation, rinsed in a tap water bath for 15 seconds at 120 F and dried using air blow off for 30 seconds at 68 F. Coupons were allowed to dry for a half an hour and then reweighed a final time. Effeciencies were calculated.

Trial Results


Success Rating
Lab evaluation based on vendor data.

Conclusion
Three of the four products were effective at removing the contaminants at an efficiency rate >94%. On may have been attacking the aluminum substrate as the removal was over 108%.