CleanerSolutions Database
Toxics Use Reduction Institute · Surface Solutions Laboratory
 
Toxics Use Reduction Institute




Surface Solutions Laboratory

Trial Report



Trial Number 422

(Client Number 153, Project Number 1)

Trial Purpose: Laboratory evaluations of alternative cleaning products

Date Run: 09/26/07

Experiment Procedure:
Cleaning : 5 min.
Immersion Soak cleaning at 130 F with stirbar agitation.
Rinsing with Tap Water
Drying : 30 sec Air blow off using hose and oulet on bench

Contaminant Soybean
Substrate 2"x 4"x 0.06" Aluminium Coupons

Trial Results


Success Rating
Lab evaluation based on vendor data.

Conclusion
Oil was left on the coupons for SC Supersolv,Valtron SP 2275 and Daraclean 235 and dripped of while drying them but there was almost no oil on the coupons used for Envirosolve.