Trial Purpose: To test nontoxic industrial cleaning solutions for oil removal

Date Run: 02/09/09

Experiment Procedure:
Products were selected based on the compatibility of substrate and removal of foreign substance. Used 10% concentration and heated the samples at 135F. The steel coupons were immersed in a product for 5 minutes, rinsed for 30 seconds in tap water at 120F and dried in 30 seconds using compressed air is room temperature.

Coupons were coated with used oil. Using a handheld swab and allowed to dry for 144 minutes at room temperature. The contaminated coupons were weighed again to determine the amount of soil added. After cleaning process the final weights were recorded, efficiencies were calculated and recorded.

Trial Results
Cleaner Initial wt   Final wt     % Removed
Spartan Chemical Corp. Graffiti Remover                        
        0.0186        0.0064        65.59
        0.0096        0.0075        21.87
        0.0189        0.0026        86.24
DFC 105                        
        0.0449        0.0021        95.32
        0.0222        0.0046        79.28
        0.0172        0.0049        71.51
Brulin Comp, Formula 815 MX-AA                        
        0.1100        0.0023        97.91
        0.0542        0.0410        24.35
        0.0153        0.0145        5.23
PolyChem, Polyspray 790                        
        0.0210        0.0176        16.19
        0.0286        0.0183        36.01
        0.0900        0.0834        7.33


Success Rating
Lab evaluation based on vendor data.

Conclusion