Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 63

Trial Purpose:

Laboratory evaluations of alternative cleaning products

Date Run:

08/02/2000

Experiment Procedure:

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Laboratory evaluation.
Contaminant: Oil, CAS: 64741-89-5, 8052-42-4
Lubricant, CAS: 8052-42-4, 64742-57-0, 64742-62-7
Grease, CAS: 64742-47-8

Trial Results:

Bio T V 50 leaves a trace of residue film on coupon.

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.