Trial Number 3

(Client Number 263, Project Number 1)

Trial Purpose: To evaluate products for oil removing using ultrasonic cleaning.

Date Run: 08/22/06

Experiment Procedure:
The two products from the previous trial were diluted to 5% in 250 ml beakers using DI water and heated to 130 F in a Branson 3510 ultrasonic tank and degassed for 5 minutes.
Six preweighed coupons were coated with the supplied oil using a hand held swab. Coupons were weighed a second time to determine the amount of buffing compound added. Three coupons were cleaned in each solution for five minutes using 40 kHz ultrasonic agitation. Coupons were rinsed for 15 seconds in a tap water bath at 120 F and dried using a dry compressed air for 30 seconds. Once dry coupons were weighed a final time and product efficiencies were calculated.

Trial Results
Both products removed over 85% of the oil using ultrasonic energy. The table below lists the amount of buffing compound added, the amount remaining
and the efficiency for each coupon cleaned.

Cleaner               Initial wt   Final wt     % Removed
Daraclean 283          0.1556       0.0256       83.55
                       0.2412       0.0156       93.53
                       0.3283       0.0180       94.52
Polyspray Jet 790 XS   0.4437       0.0340       92.34
                       0.2028       0.0417       79.44
                       0.3201       0.0457       85.72


Success Rating
A follow up test, usually based on company input.

Conclusion
With both products successful on the buffing compound and oil, the next steps will be to evaluate these cleaners on supplied parts at or after workshop.