Browse past lab clients by general industry sectors
Metal
Related Images
Project Number 1
Summary:
Several cleaners have been found to clean the contaminants. A comparison of the current cleaners to the tested products has been conducted. In-house pilot testing with SCL verification using OSEE.Test Objective:
To optimize our cleaning process. To develop a quantifiable method fro measuring part & bath cleanlinessProduct Use:
Mounting plate for an automotive sensor.Trial Number | Date Run | Purpose | Success Rating |
---|---|---|---|
0 | 06/22/1999 | To evaluate possible aqueous cleaner to be used in ultrasonic cleaning of aluminum parts. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
1 | 06/23/1999 | To evaluate six aqueous cleaner on second contaminant. | A follow up test, usually based on company input. |
2 | 06/29/1999 | To evaluate current cleaners for all three contaminants and three cleaners from previous testing on the last contaminant. | A follow up test, usually based on company input. |
3 | 07/12/1999 | To evaluate vendor recommended cleaner for all three contaminants. | A follow up test, usually based on company input. |
4 | 07/13/1999 | To clean client supplied parts using the three best cleaners. | A follow up test, usually based on company input. |
5 | 08/31/1999 | To compare parts cleaned in three different solutions using OSEE. | A cleanliness study, addressing only various analytical techniques. |