Browse past lab clients by general industry sectors
Plastics
Related Images
Project Number 1
Summary:
Three chemistries were found by the lab to clean the ink. Mirachem 500, MacDermid ND 17 and Oakite Inproclean 1300 were used in an immersion system at full strength at room temperatures for fifteen minutes.Test Objective:
Attempting to replace solvent with safer product.Product Use:
electro-mechanical switchesTrial Number | Date Run | Purpose | Success Rating |
---|---|---|---|
0 | 03/20/1996 | Find alternative to ethanol | Test incomplete or inconclusive. |
1 | 03/21/1996 | Further evaluation for ethanol replacement | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |