Browse past lab clients by general industry sectors
Metal
Related Images
Project Number 1
Summary:
Part of a joint venture between EPA, TURI and RI DEM to reduce the use of TCE in the Providence, RI area, five trials were conducted on this client’s buffing compounds. A 10% solution of Polyspray Jet 790 XS at the 150 F was the only product that was successful in cleaning the three part types supplied for cleaning. Parts have been sent back to the client for evaluation.Test Objective:
To find an alternative to TCE for removing buffing compounds from brass parts.Product Use:
Medals, decorative productsTrial Number | Date Run | Purpose | Success Rating |
---|---|---|---|
0 | 08/16/2006 | To evaluate selected products for buffing compound removal. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
1 | 08/17/2006 | To evaluate previously tested products using ultrasonic energy. | A follow up test, usually based on company input. |
2 | 08/17/2006 | To evaluate top two products at higher temperature to achieve higher efficiencies. | A follow up test, usually based on company input. |
3 | 08/22/2006 | To evaluate cleaners on water-based buffing compound using immersion cleaning. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
4 | 10/16/2006 | To evaluate selected product for cleaning supplied parts using ultrasonic energy | Results suggest a scale-up feasible match for cleaning chemistry and equipment. Pilot plant study with actual parts recommended. |
5 | 12/08/2006 | To evaluate selected product for cleaning both buffing compound and oil using supplied parts. | Results suggest a scale-up feasible match for cleaning chemistry and equipment. Pilot plant study with actual parts recommended. |
6 | 02/06/2007 | To determine if temperature or concentration were the cause for the tarnish seen on the parts cleaned during the on-site piloting. | A follow up test, usually based on company input. |
7 | 02/06/2007 | To evaluate two most effective products found for this client for tarnishing effect with solution at room temperature. | A follow up test, usually based on company input. |
8 | 02/07/2007 | To evaluate new, lower pH cleaners for cleaning brass parts that have been tarnishing with the previous cleaners we found that were effective. | A follow up test, usually based on company input. |
9 | 02/07/2007 | To evaluate selected products on a wide range of client selected parts for cleaning and tarnishing. | A follow up test, usually based on company input. |