Browse past lab clients by general industry sectors
Metal
Related Images
Project Number 1
Summary:
Part of a joint venture between EPA, TURI and RI DEM to reduce the use of TCE in the Providence, RI area, three trials were conducted on this client’s requirement of cleaning within 2 minutes (current rate with TCE) several testing parameters were adjusted and evaluated. In the end, Alconox Detergent 8 worked very well at the 10% concentration and 130 F temperature. The lower concentration (5%) also worked fairly well at 130, but had better results at the 150 F temperature. Client has requested on-site assistance for implementing the changes. TURI and EPA went to facility to conduct real-time testing.Test Objective:
To identify an alternative to TCE for cleaning brass buckles.Product Use:
Belt buckles and pinsTrial Number | Date Run | Purpose | Success Rating |
---|---|---|---|
0 | 08/31/2006 | To evaluate selected products for removing first supplied buffing compound using immersion cleaning | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
1 | 09/05/2006 | To evaluate successful cleaners on second supplied buffing compound using immersion cleaning | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
2 | 09/05/2006 | To reevaluate successful products on second supplied contaminant using ultrasonic cleaning. | A follow up test, usually based on company input. |
3 | 09/05/2006 | To evaluate one product on first supplied buffing compound using immersion cleaning. | A follow up test, usually based on company input. |
4 | 09/05/2006 | To evaluate the three successful products on the third supplied buffing compound using immersion cleaning. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
5 | 10/02/2006 | To evaluate successful cleaner at various operating conditions to meet the 2 minute cleaning time. | Results suggest a scale-up feasible match for cleaning chemistry and equipment. Pilot plant study with actual parts recommended. |
6 | 10/31/2006 | To evaluate selected cleaner using spray washing. | Results suggest a scale-up feasible match for cleaning chemistry and equipment. Pilot plant study with actual parts recommended. |
7 | 12/11/2006 | To evaluate a client requested product for cleaning buffing compounds from their brass parts. | A follow up test, usually based on company input. |