Browse past lab clients by general industry sectors
Aircraft
Project Number 1
Test Objective:
Find a safer alternative to replace TCEProduct Use:
Used for gyroscopesTrial Number | Date Run | Purpose | Success Rating |
---|---|---|---|
0 | 06/16/2020 | To evaluate the effectiveness and performance of various cleaners on the removal of rosin #4 from glass coupons. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
1 | 06/18/2020 | To evaluate the effectiveness and performance of various cleaners on the removal of rosin #4 from glass coupons with a heated immersion process. | Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary. |
2 | 07/10/2020 | The purpose of this experiment is to determine the effectiveness of seven cleaners in removing rosin from glass substrates using heated immersion. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
3 | 07/16/2020 | The purpose of this experiment was to determine the effectiveness of heated immersion with a stir bar for the removal of pitch and protect-o-coat contaminants. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
4 | 07/23/2020 | The purpose of this experiment was to evaluate the effectiveness of cleaners to remove Rosin 2 (Pitch) and Protectocoat from glass substrates using heated ultrasonics. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
5 | 07/30/2020 | The purpose of this experiment was to determine the effectiveness of high performing cleaners in removing the protect-o-coat soil from parts provided by the company with heated ultrasonics. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
6 | 10/05/2020 | The purpose of this experiment was to perform a 60-minute heated immersion test on Mirachem 500 using Contaminant #4. Test requested by company. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
7 | 10/06/2020 | The purpose of this experiment was to repeat 30 minute heated immersion with a stir bar using Mirachem 500 as requested by the company. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |