Browse past lab clients by general industry sectors
Medical
Project Number 1
Test Objective:
Identify a replacement for TCE.Product Use:
medical devicesTrial Number | Date Run | Purpose | Success Rating |
---|---|---|---|
0 | 07/31/2019 | To evaluate cleaners on their effectiveness at the removal of J2 oil using unheated immersion on titanium substrates. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
1 | 08/14/2019 | To evaluate the effectiveness of solvent and aqueous based cleaners at the removal of J2 on titanium substrates. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
2 | 08/14/2019 | To evaluate the effectiveness of solvent and aqueous based cleaners at the removal of J2 on titanium substrates. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
3 | 01/01/1970 | Five sets of 26-28 titanium parts were provided pre-contaminated with J2. Cleaners were heated to vendor recommended temperatures before immersing the parts into an ultrasonic tank for 15 minutes. Visual observations were recorded overall with notes and a set of three parts per cleaner were evaluated by three lab technicians, labelled A-C in Table 1, for cleaner and contaminant residue according using the rating key below. | Results suggest a scale-up feasible match for cleaning chemistry and equipment. Pilot plant study with actual parts recommended. |
4 | 10/21/2019 | To evaluate the dry time of two solvent products used to remove J2 oil from titanium parts. | Results suggest a scale-up feasible match for cleaning chemistry and equipment. Pilot plant study with actual parts recommended. |