Browse past lab clients by general industry sectors
Project Number 1
Test Objective:
To evaluate the removal of grease provided by the company on aluminum coupons using unheated immersion, unheated immersion with agitation, and heated immersion.Trial Number | Date Run | Purpose | Success Rating |
---|---|---|---|
0 | 10/07/2020 | To evaluate the removal of grease on aluminum coupons using unheated immersion for 15 minutes. *test* | Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary. |
1 | 10/14/2020 | To evaluate the effectiveness of cleaners/solvents for the removal of grease on aluminum substrate for 30 minutes unheated immersion. | Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary. |
2 | 10/15/2020 | To evaluate the effectiveness of cleaners/solvents for the removal of grease on aluminum substrate for 24-hour unheated immersion. | Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary. |
3 | 10/21/2020 | To evaluate the effectiveness of cleaners for the removal of grease on aluminum coupons using a stir bar at 300 rpm for 15 minutes unheated immersion | A follow up test, usually based on company input. |
4 | 10/28/2020 | To evaluate the effectiveness of cleaners and solvents for the removal of grease on aluminum coupons using a stir bar at 300 rpm with unheated immersion for 30 minutes. | A follow up test, usually based on company input. |
5 | 11/23/2020 | To evaluate the effectiveness of cleaners and solvents for the removal of grease on aluminum coupons using a stir bar with increased agitation to 500 rpm with unheated immersion for 30 minutes | A follow up test, usually based on company input. |
6 | 12/04/2020 | To evaluate the effectiveness of SW-3 Ozzy Juice for the removal of grease from aluminum coupons using heated immersion and agitation cleaning processes. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
7 | 02/18/2021 | To test the removal of grease from aluminum coupons using 30 minutes heated immersion. | Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary. |
8 | 02/18/2021 | To test the removal of grease from aluminum coupons with heated immersion for 30 minutes using stir bar. | Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary. |
9 | 03/05/2021 | To test the removal of grease on aluminum coupons using heated ultrasonics for 30 minutes. | Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary. |
10 | 03/11/2021 | To evaluate the removal of grease from aluminum coupons using heated ultrasonics at 15 minutes. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |
11 | 03/25/2021 | To test 15 and 30 minute heated ultrasonic for the removal of grease on company parts. | Test incomplete or inconclusive. |
12 | 04/01/2021 | To evaluate the effectiveness of Mirachem 500 and Dimethyl Glutarate for the removal of black grease on company parts using heated ultrasonics for 15 minutes at 105 and 120 degrees Fahrenheit. | Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. |