Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate an additional five products on the first contaminant
Date Run:
05/07/2004Experiment Procedure:
Five products were selected based on success on the fourth supplied contaminant. All five products were used at full strength in a 250 ml beaker. Two products were heated to 96 F on a hot plate and the three Dow products were used at room temperature. Twenty-seven preweighed silver plated copper coupons were coated with the Exxon Mobil Vacmul 03D (94741-44-2) using a hand held swab. Coupons were weighed a second time to determine the amount of soil added to each coupon. Three coupons were cleaned in each solution for 5 minutes using stir-bar agitation. After cleaning parts were weighed a final time and efficiencies were calculated.
Trial Results:
All five products tested on the oil removed over 97% in five minutes. The table lists the amount of soil added, the amount remaining and the efficiency for each coupon.
Cleaner | Initial wt | Final wt | % Removed |
Solvon PB | 0.0662 | -0.0003 | 100.45 |
0.1293 | 0.0011 | 99.15 | |
0.1018 | 0.0006 | 99.41 | |
Solvon IP | 0.0773 | 0.0003 | 99.61 |
0.0920 | 0.0011 | 98.80 | |
0.0770 | 0.0026 | 96.62 | |
OS 10 | 0.0997 | 0.0021 | 97.89 |
0.0839 | 0.0005 | 99.40 | |
0.0722 | 0.0014 | 98.06 | |
OS 20 | 0.0944 | 0.0038 | 95.97 |
0.0976 | 0.0018 | 98.16 | |
0.0616 | 0.0014 | 97.73 | |
OS 30 | 0.1107 | 0.0020 | 98.19 |
0.0522 | 0.0013 | 97.51 | |
0.0603 | 0.0013 | 97.84 |
Success Rating:
A follow up test, usually based on company input.Conclusion:
The three Dow products will be tested on the second supplied oil.