Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate successful products on the second supplied contaminant.
Date Run:
07/12/2004Experiment Procedure:
Five cleaners were selected from the previous trial. All products were diluted to 5% using DI water in 600 ml beakers. All nine products were heated to 120 F on a hot plate. Fifteen preweighed aluminum coupons were coated with client supplied coating, Castrol Industries Rustilo DW 924 (64742-88-7, 64742-95-6, 64741-89-5, 64741-97-5, 64742-53-6, 95-63-6), using a hand held swab and then weighed a second time to determine the amount of soil added. Three coupons were cleaned in each solution for 5 minutes using stir-bar agitation. Coupons were rinsed in tap water for 15 seconds at 120 F, followed by air blow off at room temperature. Once dry, coupons were weighed a final time and efficiencies for each cleaner were calculated.
Trial Results:
All five products removed over 99% of the rust preventative coating. The table below lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.
Cleaner | Initial wt | Final wt | % Removed |
Beyond 2004 | 0.2034 | -0.0013 | 100.64 |
0.1339 | 0.0001 | 99.93 | |
0.1758 | 0.0002 | 99.89 | |
Aeromaster | 0.1281 | 0.0007 | 99.45 |
0.1751 | 0.0004 | 99.77 | |
0.1752 | 0.0004 | 99.77 | |
1400 GD | 0.3453 | 0.0001 | 99.97 |
0.2659 | -0.0003 | 100.11 | |
0.2920 | -0.0004 | 100.14 | |
M Aero | 0.2214 | -0.0003 | 100.14 |
0.2546 | -0.0007 | 100.27 | |
0.1804 | -0.0002 | 100.11 | |
815 QR | 0.2150 | -0.0002 | 100.09 |
0.1106 | -0.0002 | 100.18 | |
0.2082 | -0.0003 | 100.14 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.Conclusion:
The same five products will be used on the third supplied contaminant under the same conditions.