Browse past lab clients by general industry sectors
Trial Purpose:
To reevaluate products on supplied parts.
Date Run:
07/27/2004Experiment Procedure:
Five products that were found to be effective on all three soils were used at 120 F in a Crest Ultrasonic 40 KHz tank. Four products were used at 5% dilutions in 600 ml beakers and the fifth was used as received from the client in a 400 ml beaker. Each beaker was submersed in the tank filled with water at 120 F and degassed for 5 minutes.
The preweighed parts were contaminated with Castrol Rustilo 4163 (64742-46-7, 8002-74-2, 34590-94-8)and the weighed again. Five parts were cleaned in each product for five minutes with ultrasonic energy. The parts were rinsed in tap water at 120 F for 30 seconds and dried using air blow off at room temperature for 30 seconds. Parts were weighed a final time and efficiencies were calculated. Parts were then packaged and sent back to client to determine effectiveness.
Trial Results:
The five products appeared to remove all of the Rustilo. Only two parts with ball bearings had less than 95% removal with ultrasonics. The table below lists the initial soil weight, final weight and cleaning efficiency for each part cleaned.
Initial wt | Final wt | % Removed | |
Beyond 2004 | 0.4902 | -0.0001 | 100.02 |
0.1483 | 0.0001 | 99.93 | |
0.409 | -0.0010 | 100.24 | |
0.3925 | 0.0206 | 94.75 (ball bearing) | |
0.0397 | -0.0016 | 104.03 | |
Aeromaster | 0.1285 | 0.0005 | 99.61 |
0.1798 | 0.0001 | 99.94 | |
0.4602 | 0.0037 | 99.20 | |
0.2213 | 0.0159 | 92.82 (ball bearing) | |
0.0811 | -0.0004 | 100.49 | |
M-Aero | 0.1325 | 0.0001 | 99.92 |
0.1835 | -0.0010 | 100.54 | |
0.4464 | -0.0006 | 100.13 | |
2.1066 | -0.0002 | 100.01 | |
0.0113 | -0.001 | 108.85 | |
815 QR | 0.1665 | -0.0012 | 100.72 |
0.1416 | -0.0005 | 100.35 | |
0.3838 | -0.0006 | 100.16 | |
0.3373 | -0.0005 | 100.15 | |
0.0757 | -0.0012 | 101.59 | |
Alkalume | 0.1018 | 0.0006 | 99.41 |
0.1244 | -0.0012 | 100.96 | |
0.3699 | -0.0004 | 100.11 | |
0.1326 | -0.0010 | 100.75 | |
0.0225 | -0.0004 | 101.78 |
Success Rating:
A follow up test, usually based on company input.Conclusion: