Browse past lab clients by general industry sectors
Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
07/06/1999Experiment Procedure:
Nine products were used at 5% dilutions and heated to 130 F. Stainless steel coupons were coated with Keystone KSL 111 Synthetic Tacky Grease (64742-47-8). Coupons were rinsed with tap water for 2 minutes.
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
Multikleen LX 1573 removed 98% of the grease