Browse past lab clients by general industry sectors
Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
01/15/2002Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Degasing: Cleaners were kept in ultrasonic crest for 5 min. at 120 F.
Cleaning : 2 min. in ultrasonic crest at 120 F.
Rinsing :1/2 min immersion cleaning at 120 F in water.
Drying :1 min. with heat gun at 500 F.
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
All cleaners were effective.