Browse past lab clients by general industry sectors
Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
01/17/2002Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Degasification: 5 min. in ultrasonic crest at 120 F.
Cleaning: 2 min. in ultrasonic crest at 120 F.
Rinsing: 1/2 min. manual with water at 120 F.
Drying: 1 min. with heat gun at 500 F.
Contaminant: Latex binder mix (00146)
Cas #: 9016-45-9, 766
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.