Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
04/10/2002Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Degasifying: cleaners were kept in ultrasonic tank for 5 min. at 120 F.
Cleaning: 2 min. in ultrasonic at 120 F.
Rinsing: 1/2 min. manual with water at 120 F.
Drying: 1 min. with heat gun at 500 F.
Lubricant - ITW fluid product group, Accu-Lube, PS 8 Spray Lubricant
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
All the cleaners were effective.