Browse past lab clients by general industry sectors
Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
09/10/2002Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Degassing: Degassing the solution by keeping solutions in ultrasonic crest for 2 min at 120 F.
Cleaning: Ultrasonic for 2 min. at 120 F.
Rinsing: 1/2 min. manual with water at 120 F.
Drying: 1 min with heat gun @ 500F
Contaminant: Steco Corp, Tap Magic Protap (cutting fluid)
CAS# 112-80-1(>75%) Aliphatic organic acid
112-62-9 (<15%) Aliphatic organic ester
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
Heated ultrasonics did not change efficiency significantly.