Browse past lab clients by general industry sectors
Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
09/22/2003Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Six products were used at full strength, heated to 120 F on a hot plate. Eighteen preweighed coupons were coated with Dauber Chemical Co Tectyl 891 Class 1 Cosmoline grease (8052-41-3, 98918-69-4, 64742-65-0, 68608-26-4) and allowed to dry for three days and reweighed. Three coupons were cleaned in each solution for 5 minutes using stir-bar-agitation, rinsed in a tap water bath for 15 seconds at 120 F and dried using air blow off for 30 seconds at 68 F. Coupons were allowed to dry overnight and then reweighed a final time. Efficiencies were calculated.
Note: Bio T Foam Plus was sprayed onto coupons at room temperature and allowed to sit for 5 minutes. The cleaner was then rinsed off.
Trial Results:
Only one product removed over 85% of the soil during the 5-minute immersion cleaning. A second product removed just under 70%.
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
Increased cleaning time or the addition of agitation would improve the cleaning for 278 Super Solv and VG 151.