Browse past lab clients by general industry sectors
Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
05/26/2004Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
All products were used heated to 96 F on a hot plate in 250 ml beakers. Eighteen preweighed steel coupons were coated with a varnish mix containing Cooper's Creek Chemicals, Cooper Black Tank Paint No 739 (64742-89-8, 8052-42-4, 108-88-3); Sherwin Williams Company, V74B2 Black Asphaltum coating (64742-89-8, 64742-88-7, 8052-42-4) using a handheld swab. The oil was then heated with a Master Appliance Heat gun at 300 F for 10 minutes. After cooling to room temperature, a second weighing was performed to determine the amount of soil that was added. Three coupons were cleaned in each solution for 5 minutes with minimal stir-bar agitation. After drying, coupons were weighed a final time to determine the cleaning efficiency of each product.
Trial Results:
Cleaner | Initial wt | Final wt | % Removed |
Vertrel MCA | 0.1033 | 0.0490 | 52.57 |
0.0739 | 0.0587 | 20.57 | |
0.4764 | 0.1710 | 64.11 | |
Heavy Duty Degreaser C | 0.4009 | 0.1452 | 63.78 |
0.1833 | 0.1334 | 27.22 | |
0.4228 | 0.3069 | 27.41 | |
HFE 7100 | 0.2702 | 0.1881 | 30.38 |
0.3106 | 0.2235 | 28.04 | |
0.0964 | 0.0768 | 20.33 | |
OS 10 | 0.1747 | 0.1165 | 33.31 |
0.6643 | 0.4647 | 30.05 | |
0.2005 | 0.1801 | 10.17 | |
OS 20 | 0.1024 | 0.0755 | 26.27 |
0.1767 | 0.1214 | 31.30 | |
0.4048 | 0.2911 | 28.09 | |
OS 30 | 0.0619 | 0.0582 | 5.98 |
0.3670 | 0.2762 | 24.74 | |
0.0697 | 0.0646 | 7.32 |
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
No product removed over 50% of the contaminant.