Browse past lab clients by general industry sectors
Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
07/06/2004Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Cleaning: 5 min. immersion cleaning at 96 F with stir-bar agitation.
NO Rinsing
Drying: 30 sec. Air blow off using hose
Contaminant:
Oil Nisseki SAS 40 CAS# 2776-01-8, 612-00-00, 103-29-7, 101-81-5
Substrate 2 " x 2" aluminum
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
They all were effective, again ES & GS were slightly above 102% (0.5 & 0.7) but again we believe this is due to removing films or buildup form the coupons effectively since there was no visible signs of deterioration of the coupon.