Browse past lab clients by general industry sectors
Trial Purpose:
Laboratory evaluations of alternative cleaning products
Date Run:
09/26/2007Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Cleaning: 5 min.
Immersion Soak cleaning at 130 F with stir-bar agitation.
Rinsing with Tap Water
Drying: 30 sec Air blow off using hose and outlet on bench
Contaminant Soybean
Substrate 2"x 4"x 0.06" Aluminum Coupons
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
Oil was left on the coupons for SC Supersolv,Valtron SP 2275 and Daraclean 235 and dripped of while drying them but there was almost no oil on the coupons used for Envirosolve.