Browse past lab clients by general industry sectors
Trial Purpose:
removing cutting fluid off of the surface of aluminum by using non-toxic cleaners.
Date Run:
04/09/2008Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Products were based on the compatibility of substrate and removal of foreign substance. Used 5% concentration and heated the samples at 135F. The coupons were immersed in a product for 5 minutes, rinsed for 30 seconds in tap water at 120F and dried in 30 seconds
Trial Results:
Cleaner | Initial wt | Final wt | % Removed |
aquavantage 1400 GD | |||
0.9980 | 0.0412 | 95.87 | |
0.7371 | 0.0398 | 94.60 | |
0.8273 | 0.0116 | 98.60 | |
Amberclean L12 | |||
1.1533 | 0.0028 | 99.76 | |
0.8348 | 0.0018 | 99.78 | |
0.4512 | 0.0063 | 98.60 | |
Seawash Blue | |||
0.9970 | 0.0144 | 98.56 | |
0.8899 | 0.0143 | 98.39 | |
0.8744 | 0.0092 | 98.95 | |
SC aircraft and metal cleaner | |||
0.5912 | 0.0578 | 90.22 | |
0.9434 | 0.0421 | 95.54 | |
0.7929 | 0.0634 | 92.00 |
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
All products tested has passed the contaminant removal of 85% or higher.