Trial Purpose:
Removing moxoline 75 off of the surfaces of aluminum by using non-toxic cleaning products.
Date Run:
05/08/2008Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Products were based on the compatibility of substrate and removal of foreign substance. Used 5% concentration and heated the samples at 135F. The coupons were immersed in a product for 5 minutes, rinsed for 30 seconds in tap water at 120F and dried in 30 seconds.
Trial Results:
Cleaner | Initial wt | Final wt | % Removed |
ozzy sw-3 | |||
0.4427 | 0.0221 | 95.01 | |
0.2433 | 0.0276 | 88.66 | |
0.3277 | 0.0382 | 88.34 | |
sea wash blue | |||
0.4979 | 0.0092 | 98.15 | |
0.4785 | 0.0165 | 96.55 | |
0.3594 | 0.0184 | 94.88 | |
ozzy sw-1 | |||
0.3148 | 0.0576 | 81.70 | |
0.4314 | 0.0521 | 87.92 | |
0.3486 | 0.0475 | 86.37 | |
nab 9000 | |||
0.5169 | 0.0864 | 83.28 | |
0.3653 | 0.0444 | 87.85 | |
0.4019 | 0.0272 | 93.23 | |
california parts washer | |||
0.4907 | 0.0051 | 98.96 | |
0.7297 | 0.0049 | 99.33 | |
0.4705 | 0.0064 | 98.64 | |
valtron sp 2275 | |||
0.3918 | 0.0847 | 78.38 | |
0.3723 | 0.0998 | 73.19 | |
0.6877 | 0.0554 | 91.94 |
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
All products in this lab surpassed the passing removal rate of 85% or higher.