Browse past lab clients by general industry sectors
Trial Purpose:
To remove maintenance soil from stainless steel using ultrasonic cleaning
Date Run:
06/17/2008Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Products were selected based on the compatibility of substrate and for removal of the contaminant. Five percent concentrations were used and heated the samples at 104 F. The coupons were cleaned in a product for 20 minutes using ultrasonic cleaning, rinsed with tap water at 105 F and dried at room temperature using compressed air blow off. Coupons were coated with used maintenance soil using a handheld swab and allowed to dry for 20 minutes at room temperature. The contaminated coupons were weighed again to determine the amount of soil added. After cleaning process, the final weights were recorded, efficiencies were calculated and recorded.
Trial Results:
Cleaner | Initial wt | Final wt | % Removed |
Inproclean 3800 | |||
0.1008 | 0.0188 | 81.35 | |
0.1001 | 0.0128 | 87.21 | |
0.0943 | 0.0187 | 80.17 | |
Polyspray Jet 790 XS | |||
0.0926 | 0.1061 | -14.58 | |
0.1650 | 0.0592 | 64.12 | |
0.1280 | 0.0211 | 83.52 | |
Micro 90 | |||
0.0781 | 0.0189 | 75.80 | |
0.0975 | 0.0442 | 54.67 | |
0.1504 | 0.0272 | 81.91 | |
Shopmaster LpH | |||
0.1253 | 0.0643 | 48.68 | |
0.1129 | 0.0957 | 15.23 | |
0.1067 | 0.0457 | 57.17 | |
BG Solve 717 | |||
0.1062 | 0.0228 | 78.53 | |
0.0995 | 0.0515 | 48.24 | |
0.1066 | 0.1016 | 4.69 | |
Hurrisafe 9450 | |||
0.1322 | 0.0587 | 55.60 | |
0.1010 | 0.0634 | 37.23 | |
0.1070 | 0.0698 | 34.77 | |
Daraclean 282 GF | |||
0.1254 | 0.0749 | 40.27 | |
0.1126 | 0.0809 | 28.15 | |
0.0970 | 0.0527 | 45.67 |
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
No product removed over 85%. Inproclean 3800 removed about 83%.