Browse past lab clients by general industry sectors
Trial Purpose:
To remove vanishing cutting fluid from aluminum using immersion cleaning
Date Run:
07/29/2008Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Products were selected based on the compatibility of substrate and for removal of the contaminant. Five percent concentrations were used and heated the samples at 130F. The coupons were immersed in a product for 5 minutes, rinsed with tap water and dried using room temperature compressed air. Coupons were coated with vanishing cutting fluid using a handheld swab and allowed to dry for one hour at room temperature. The contaminated coupons were weighed again to determine the amount of soil added. After cleaning process, the final weights were recorded, efficiencies were calculated and recorded.
Trial Results:
Cleaner | Initial wt | Final wt | % Removed |
Daraclean 235 | |||
0.2522 | 0.1096 | 56.54 | |
0.2164 | 0.1429 | 33.96 | |
0.2988 | 0.1172 | 60.78 | |
SC Supersolv | |||
0.3029 | 0.0522 | 82.77 | |
0.3728 | 0.0578 | 84.50 | |
0.4659 | 0.0578 | 87.59 | |
Bio T Max | |||
0.4027 | 0.0682 | 83.06 | |
0.4454 | 0.0521 | 88.30 | |
0.4020 | 0.0543 | 86.49 | |
Sea Wash Blue | |||
0.3693 | 0.1035 | 71.97 | |
0.4483 | 0.1038 | 76.85 | |
0.3500 | 0.1499 | 57.17 | |
Valtron SP 2275 | |||
0.6383 | 0.1025 | 83.94 | |
0.5283 | 0.0970 | 81.64 | |
0.9955 | 0.1000 | 89.95 | |
SC Aircraft & Metal Cleaner | |||
0.8885 | 0.1547 | 82.59 | |
0.6062 | 0.1489 | 75.44 | |
0.7274 | 0.1341 | 81.56 |
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
Three of the six products removed over 85% of the cutting fluid using heated immersion cleaning.