Browse past lab clients by general industry sectors
Trial Purpose:
To test nontoxic industrial cleaning solutions for oil removal
Date Run:
02/09/2009Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Products were selected based on the compatibility of substrate and removal of foreign substance. Used 10% concentration and heated the samples at 135F. The steel coupons were immersed in a product for 5 minutes, rinsed for 30 seconds in tap water at 120F and dried in 30 seconds using compressed air is room temperature.
Trial Results:
Cleaner | Initial wt | Final wt | % Removed |
Kyzen Corporation, Industrial Floor | |||
0.1275 | 0.0307 | 75.92 | |
0.1276 | 0.1013 | 20.61 | |
0.2384 | 0.0604 | 74.66 | |
Vertec BioSolvents | |||
0.1113 | 0.0193 | 82.66 | |
0.2803 | 0.0046 | 98.36 | |
0.2909 | 0.0440 | 84.87 | |
Seventh Generation | |||
0.2615 | 0.0364 | 86.08 | |
0.1409 | 0.0276 | 80.41 | |
0.2068 | 0.0377 | 81.77 | |
Sky Product Cleaner | |||
0.0516 | 0.0316 | 38.76 | |
0.3475 | 0.0810 | 76.69 | |
0.2288 | 0.0231 | 89.90 |
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
One product removed over 85% of the grease from stainless steel using immersion cleaning.