Browse past lab clients by general industry sectors
Trial Purpose:
To remove ink from steel using immersion cleaning.
Date Run:
02/12/2009Experiment Procedure:
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Products were selected based on the compatibility of substrate and for removal of the contaminant. Ten percent concentrations were used and heated the samples at 130F. The coupons were immersed in a product for 5 minutes, rinsed in tap water at 120 F and dried using compressed air at room temperature. Coupons were coated with the ink contaminant using a handheld swab and allowed to dry for 120 minutes at room temperature. The contaminated coupons were weighed again to determine the amount of soil added. After cleaning process, the final weights were recorded, efficiencies were calculated and recorded.
Trial Results:
Cleaner | Initial wt | Final wt | % Removed |
Sea Wash Cleaner | |||
0.5090 | 0.1210 | 76.23 | |
0.1896 | 0.0748 | 60.55 | |
0.1077 | 0.0773 | 28.23 | |
Simple Green D | |||
0.2494 | 0.0309 | 87.61 | |
0.1389 | 0.0134 | 90.35 | |
0.5746 | 0.1027 | 82.13 | |
Micro 90 | |||
0.2816 | 0.1995 | 29.15 | |
0.1753 | 0.1754 | -0.06 | |
0.4178 | 0.4014 | 3.93 | |
SC Aircraft | |||
0.4232 | 0.2773 | 34.48 | |
0.2433 | 0.2392 | 1.69 | |
0.3573 | 0.3360 | 5.96 | |
Soy Gold 1000 | |||
0.3248 | 0.3288 | -1.23 | |
0.6573 | 0.4067 | 38.13 | |
0.1643 | 0.1227 | 25.32 | |
Maxi Solv | |||
0.1977 | 0.0794 | 59.84 | |
0.3112 | 0.1629 | 47.65 | |
0.7608 | 0.0790 | 89.62 | |
SWR One | |||
0.3892 | 0.2786 | 28.42 | |
1.1775 | 0.3356 | 71.5 | |
0.2693 | 0.0401 | 85.11 |
Success Rating:
Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.Conclusion:
Three of the products removed more than 85% of the ink from the steel coupons using immersion cleaning.