Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate successful products on second supplied contaminant
Date Run:
05/06/2004Experiment Procedure:
Nine cleaners were selected based on client request for vapor degreasing solvents. All products were used heated to 96 F on a hot plate in 250 ml beakers. The process utilized no water rinse and only used ambient air to dry the parts.
Twenty-seven preweighed steel coupons were coated with Rochester Midland RI780 rust preventative (80252-41-3, 95-63-6) using a hand held swab. The oil was then heated with a Master Appliance Heat gun at 300 F for 10 minutes. After cooling to room temperature, a second weighing was performed to determine the amount of soil that was added. Three coupons were cleaned in each solution for 5 minutes with minimal stir-bar agitation. After drying, coupons were weighed a final time to determine the cleaning efficiency of each product.
Trial Results:
All nine products removed over 90% of the soil during the five minutes. Four of the products removed over 97%. The table lists the amount of soil added, the amount remaining and the efficiency for each coupon.
Cleaner | Initial wt | Final wt | % Removed |
Ak 225 | 0.0378 | 0.0014 | 96.30 |
0.0284 | 0.0021 | 92.61 | |
0.0531 | 0.0017 | 96.80 | |
Vertrel CCA | 0.0303 | 0.0005 | 98.35 |
0.0273 | 0.0015 | 94.51 | |
0.0647 | 0.0016 | 97.53 | |
Flux Remover C | 0.0241 | 0.0023 | 90.46 |
0.0728 | 0.0007 | 99.04 | |
0.0824 | 0.0019 | 97.69 | |
HFE 7200 | 0.0411 | 0.0012 | 97.08 |
0.0753 | 0.0003 | 99.60 | |
0.0731 | 0.0005 | 99.32 | |
Ensolv | 0.0300 | 0.0032 | 89.33 |
0.0566 | 0.0000 | 100.00 | |
0.0459 | 0.0022 | 95.21 | |
Ensolv A | 0.0387 | 0.0016 | 95.87 |
0.0652 | 0.0014 | 97.85 | |
0.0465 | 0.0011 | 97.63 | |
Metalnox M6960 | 0.0261 | 0.0025 | 90.42 |
0.0413 | 0.0044 | 89.35 | |
0.0352 | 0.0016 | 95.45 | |
Solvon PB | 0.0341 | 0.0018 | 94.72 |
0.0497 | 0.0001 | 99.80 | |
0.0282 | 0.0003 | 98.94 | |
Solvon IP | 0.0425 | 0.0012 | 97.18 |
0.0210 | 0.0006 | 97.14 | |
0.0272 | 0.0009 | 96.69 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.Conclusion:
All nine products will be tested on the third soil under the same conditions.