Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate five products on the fourth supplied soil
Date Run:
05/12/2004Experiment Procedure:
Five cleaners were selected from the previous trial. All were aqueous based and were diluted to 5% using DI water in 600 ml beakers. All six products were heated to 120 F on a hot plate.
Fifteen preweighed titanium coupons were coated with client supplied peanut oil, using a hand held swab and then weighed a second time to determine the amount of soil added. Three coupons were cleaned in each solution for 5 minutes using stir-bar agitation. Coupons were rinsed in tap water for 15 seconds at 120 F, followed by air blow off at room temperature. Once dry, coupons were weighed a final time and efficiencies for each cleaner were calculated.
Trial Results:
All five products removed over 98% of the oil in five minutes. Three of the five removed over 99%. The table lists the amount of oil added, the amount remaining and the efficiency for each coupon.
Cleaner | Initial wt | Final wt | % Removed |
SC Aircraft & Metal Cleaner | 0.1518 | 0.0024 | 98.42 |
0.1971 | 0.0012 | 99.39 | |
0.0836 | 0.0024 | 97.13 | |
Micro 90 | 0.1452 | 0.0003 | 99.79 |
0.0777 | -0.0003 | 100.39 | |
0.1994 | 0.0005 | 99.75 | |
Daraclean 282 GF | 0.0870 | 0.0006 | 99.31 |
0.1537 | 0.0005 | 99.67 | |
0.0984 | 0.0003 | 99.70 | |
Inproclean 3800 | 0.1430 | -0.0001 | 100.07 |
0.1101 | 0.0002 | 99.82 | |
0.1125 | 0.0004 | 99.64 | |
Beyond 2004 | 0.1036 | 0.0004 | 99.61 |
0.1144 | 0.0019 | 98.34 | |
0.2136 | 0.0038 | 98.22 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.Conclusion:
The five products will all be tested on the flux. In addition, a few other products will be added for evaluation.