Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate top five products on third supplied contaminant using manual cleaning
Date Run:
10/28/2009Experiment Procedure:
Five products from the previous trials were selected based on performance. All were used at room temperature. Two alkaline aqueous cleaners were diluted to 5% using DI water in 300 ml beakers. Three cleaners were used at full strength. Fifteen preweighed aluminum coupons were coated with Mobile DTE 25 oil using a handheld swab. The contaminated coupons were weighed again to determine the amount of soil added.
Each cleaner tested with three coupons. Three coupons were placed into a Gardner Straight Line Washability unit. A Kimberly Clark Reinforced paper towel was attached to the cleaning sled and soaked with 5-7 sprays of cleaning solutions. Each coupon was sprayed 3 times with the same cleaning solution. First, Coupon was cleaned for 15 cycles two times; after coupon was cleaned for 15 cycles, experimenter changed the paper towel and soaked with 5 spray of same cleaning solution. At the end of the cleaning, coupons were dried at room temperature naturally. Final weights were recorded and efficiencies were calculated and recorded.
Trial Results:
All five products removed more than 90% of the oil from the aluminum coupons using simulated manual cleaning. The table lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.
Cleaner | Initial wt | Final wt | % Removed |
Buckerye_Shopmater RC 100% | |||
0.1004 | 0.0128 | 87.25 | |
0.2172 | 0.0142 | 93.46 | |
0.2324 | 0.0156 | 93.29 | |
Gemtek_SC Aircrafe metal cleaner 5% | |||
0.2534 | 0.0128 | 94.95 | |
0.2249 | 0.0114 | 94.93 | |
0.2654 | 0.0067 | 97.48 | |
Biochem_Solsafe 245 100% | |||
0.2059 | 0.0139 | 93.25 | |
0.2127 | 0.0135 | 93.65 | |
0.2246 | 0.0093 | 95.86 | |
Alconox_Detergent 8 5% | |||
0.1148 | 0.0091 | 92.07 | |
0.2454 | 0.0083 | 96.62 | |
0.2292 | 0.0103 | 95.51 | |
Activion | |||
0.2715 | 0.0175 | 93.55 | |
0.2483 | 0.0103 | 95.85 | |
0.2557 | 0.0183 | 92.84 |
Success Rating:
A follow up test, usually based on company input.Conclusion:
The same five products will be tested on the fourth supplied soil under the same conditions.