Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate top five products on eight supplied contaminant using manual cleaning
Date Run:
11/12/2009Experiment Procedure:
Five products from the previous trials were selected based on performance. All were used at room temperature. Two alkaline aqueous cleaners were diluted to 5% using DI water in 300 ml beakers. Three cleaners were used at full strength. Fifteen preweighed aluminum coupons were coated with Lennox synthetic lubricant using a handheld swab. The contaminated coupons were weighed again to determine the amount of soil added.
Each cleaner tested with three coupons. Three coupons were placed into a Gardner Straight Line Washability unit. A Kimberly Clark Reinforced paper towel was attached to the cleaning sled and soaked with 5-7 sprays of cleaning solutions. Each coupon was sprayed 3 times with the same cleaning solution. First, Coupon was cleaned for 15 cycles two times; after coupon was cleaned for 15 cycles, experimenter changed the paper towel and soaked with 5 spray of same cleaning solution. At the end of the cleaning, coupons were dried at room temperature naturally. Final weights were recorded and efficiencies were calculated and recorded.
Trial Results:
All five worked well on the oil, removing more than 95%. The table lists the amount of oil added, the amount remaining and the efficiency for each coupon cleaned.
Cleaner | Initial wt | Final wt | % Removed |
Shopmater RC 100% | |||
0.0713 | 0.0007 | 99.02 | |
0.0750 | 0.0005 | 99.33 | |
0.0800 | 0.0011 | 98.62 | |
SC Aircraft metal cleaner 5% | |||
0.0978 | 0.0039 | 96.01 | |
0.0859 | 0.0008 | 99.07 | |
0.0650 | 0.0000 | 100.00 | |
Solsafe 245 100% | |||
0.1140 | 0.0052 | 95.44 | |
0.0783 | 0.0033 | 95.79 | |
0.0786 | 0.0011 | 98.60 | |
Detergent 8 5% | |||
0.0602 | 0.0005 | 99.17 | |
0.0558 | 0.0005 | 99.10 | |
0.0572 | -0.0017 | 102.97 | |
Activeion | |||
0.0547 | 0.0003 | 99.45 | |
0.0709 | 0.0088 | 87.59 | |
0.0595 | -0.0018 | 103.03 |
Success Rating:
A follow up test, usually based on company input.Conclusion:
Based on past performance on the previous contaminants, all five products will be tested on supplied parts under the same conditions.