Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate alternative cleaners on second supplied contaminant.
Date Run:
05/16/2007Experiment Procedure:
Six products from the previous trial were selected and used at full strength. The cleaning solutions were all heated to 130 F on a hot plate.
Eighteen preweighed alloy coupons were coated with the second supplied lubricant and weighed a second time to determine the amount of contaminant added to each coupon. Three coupons were immersed into each solution and cleaned for 5 minutes using stir-bar agitation. Coupons were rinsed in room temperature tap water for 15 seconds and air dried using compressed dry air for 30 seconds. A final weight was recorded, and efficiencies were calculated for each coupon cleaned.
Trial Results:
Five of the six products removed over 95% of the lubricant. Three of these removed over 99%. The table below lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.
Cleaner | Initial wt | Final wt | % Removed |
Soy Gold 1100 | 1.4978 | 0.0286 | 98.09 |
1.5557 | 0.0541 | 96.52 | |
1.5184 | 0.0291 | 98.08 | |
Solsafe 245 | 1.9557 | 0.0186 | 99.05 |
1.9062 | 0.0077 | 99.60 | |
2.1998 | 0.0053 | 99.76 | |
Shopmaster RC | 2.1195 | 0.0117 | 99.45 |
1.8953 | 0.0095 | 99.50 | |
1.2542 | 0.0080 | 99.36 | |
DS 108 | 2.2218 | 0.0181 | 99.19 |
1.7480 | 0.0167 | 99.04 | |
1.3172 | 0.0106 | 99.20 | |
D Greeze 500 LO | 2.1602 | 0.1368 | 93.67 |
1.5610 | 0.0311 | 98.01 | |
2.0320 | 0.0392 | 98.07 | |
SC Supersolve | 1.8005 | 0.5534 | 69.26 |
2.2033 | 0.4855 | 77.96 | |
1.8246 | 0.5985 | 67.20 |
Success Rating:
Results suggest a scale-up feasible match for cleaning chemistry and equipment. Pilot plant study with actual parts recommended.Conclusion:
The five products that removed over 95% will be tested on the third supplied contaminant under the same conditions.