Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate top alternatives on third supplied contaminant.
Date Run:
05/16/2007Experiment Procedure:
Five products from the previous trial were selected and used at full strength based on past performance. The cleaning solutions were all heated to 130 F on a hot plate.
Fifteen preweighed alloy coupons were coated with the third supplied lubricant and weighed a second time to determine the amount of contaminant added to each coupon. Three coupons were immersed into each solution and cleaned for 5 minutes using stir-bar agitation. Coupons were rinsed in room temperature tap water for 15 seconds and air dried using compressed dry air for 30 seconds. A final weight was recorded, and efficiencies were calculated for each coupon cleaned.
Trial Results:
All five of the products removed over 90% of the lubricant. All but one removed over 95% and two of these removed over 97%. The table below lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.
Cleaner | Initial wt | Final wt | % Removed |
Soy Gold 1100 | 0.4782 | 0.0441 | 90.78 |
0.3664 | 0.0353 | 90.37 | |
0.4703 | 0.0279 | 94.07 | |
Solsafe 245 | 0.4263 | 0.0187 | 95.61 |
0.5162 | 0.0109 | 97.89 | |
0.5374 | 0.0425 | 92.09 | |
Shopmaster RC | 0.3993 | 0.0263 | 93.41 |
0.4303 | 0.0141 | 96.72 | |
0.5563 | 0.0203 | 96.35 | |
DS 108 | 0.3071 | 0.0107 | 96.52 |
0.3295 | 0.0097 | 97.06 | |
0.3694 | 0.0078 | 97.89 | |
D Greeze 500 LO | 0.5063 | 0.0146 | 97.12 |
0.4665 | 0.0085 | 98.18 | |
0.3407 | 0.0133 | 96.10 |
Success Rating:
Results suggest a scale-up feasible match for cleaning chemistry and equipment. Pilot plant study with actual parts recommended.Conclusion:
The effective products will be tested on the fourth supplied contaminant following the same laboratory procedures.