Trial Purpose:
To evaluate follow up products on flux removal.
Date Run:
11/07/2008Experiment Procedure:
Five products were used at full strength and room temperature for removing the supplied flux. Coupons were coated with two layers of the RMA flux using a handheld swab. The coupons were manually wiped using the same method as previous trials, soaking the rag and wiping the surface. Time to remove the flux was recorded.
Trial Results:
All five of the products removed the flux within 10 seconds of the manual wiping. The table lists the amount of time required to remove the flux from the glass surface.
Product | Time |
Free & Clear | 4 seconds - possible film |
Scout Glass & Surface | 6 seconds |
Kernel Clean | 6 seconds - possible film |
Clean Environment Glass | 5 seconds |
SC More Than Glass | 7 seconds |
Success Rating:
A follow up test, usually based on company input.Conclusion:
All five products are good candidates for on-site piloting.