Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate top performing products on fourth supplied contaminant using immersion cleaning.
Date Run:
10/10/2008Experiment Procedure:
The top five products based on past testing results were again diluted to 5% using DI water in 400 ml beakers. All five products were heated to 130 F on a hot plate. Peweighed aluminum coupons were coated with the Hagsterfer's Hard Cut 5318 cutting oil using a handheld swab. The contaminant was allowed to dry for about 10 minutes. Once dry, the coupons were weighed a second time to determine the amount of oil applied.
Three coupons were immersed into each solution and cleaned for 5 minutes using stir-bar agitation. Rinsing was performed for 15 seconds using tap water heated to 120 F and followed by 30 seconds of air blow off with dry compressed air at room temperature. Final weights were recorded, and efficiencies were calculated for each coupon cleaned.
Trial Results:
Not all of the products were effective at removing the cutting oil from the aluminum coupons within 5 minutes of immersion cleaning. Three of the five removed over 80% of the cutting fluid. The other two removed between 70 and 75%. The table lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.
Cleaner | Initial wt | Final wt | % Removed |
Green Soak | 0.1416 | 0.0538 | 62.01 |
0.2755 | 0.0310 | 88.75 | |
0.1838 | 0.0430 | 76.61 | |
Shopmaster LpH | 0.2743 | 0.0572 | 79.15 |
0.1377 | 0.0083 | 93.97 | |
0.1811 | 0.0389 | 78.52 | |
FPC 100 | 0.1386 | 0.0434 | 68.69 |
0.1963 | 0.0801 | 59.20 | |
0.3006 | 0.0417 | 86.13 | |
SC Aircraft & Metal Cleaner | 0.2222 | 0.0264 | 88.12 |
0.2050 | 0.0257 | 87.46 | |
0.2183 | 0.0095 | 95.65 | |
Amberclean L12 | 0.2221 | 0.0327 | 85.28 |
0.1871 | 0.0408 | 78.19 | |
0.3836 | 0.0379 | 90.12 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.Conclusion:
The top products will be evaluated on the fifth supplied contaminant under the same cleaning conditions.