Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate the efficiency of various heated drop in solvent replacement in removing Momentive Grease from Stainless Steel .
Date Run:
03/04/2016Experiment Procedure:
Stainless steel coupons were weighed to get their initial weights. The bottom third of each coupon was coated in the Momentive Grease. The coupons were re- weighed. The weights were recorded. The coupons were placed in the heated drop-in solvent replacement for 5 minutes. The coupons were removed out of the cleaning solution and placed to dry on a rack for 15 minutes. Then the final weights were taken and recorded.
Trial Results:
Cleaner | Initial wt | Final wt | % Removal |
Ethyl 408 | 0.2458 | 0.2605 | -5.98 |
0.2095 | 0.2170 | -3.58 | |
0.1481 | 0.1671 | -12.83 | |
Methyl 408 | 0.1141 | 0.1132 | 0.79 |
0.1298 | 0.1323 | -1.93 | |
0.1071 | 0.1059 | 1.12 | |
FluoSolv CX | 0.1209 | 0.0700 | 2.10 |
0.1269 | 0.0501 | 0.60 | |
0.1509 | 0.1000 | 33.73 | |
FluoSolv NC | 0.0981 | 0.0261 | 73.94 |
0.1151 | 0.0447 | 61.16 | |
0.1020 | 0.0295 | 71.08 | |
Honeywell PF | 0.2921 | 0.2482 | 15.03 |
0.2131 | 0.1560 | 26.79 | |
0.2353 | 0.1711 | 27.28 | |
Honeywell PF 2A | 0.2094 | 0.1483 | 29.18 |
0.2195 | 0.1284 | 41.50 | |
0.1477 | 0.0788 | 46.65 | |
Vertrel Sion | 0.1717 | 0.0588 | 65.75 |
0.1450 | 0.0366 | 74.76 | |
0.1832 | 0.0341 | 81.39 | |
Fluosolv CX-500 | 0.7259 | 0.7089 | 2.34 |
0.6435 | 0.6205 | 3.57 | |
0.5512 | 0.5302 | 3.81 | |
Fluosolv FR-110 | 0.3911 | 0.3690 | 5.65 |
0.2871 | 0.2694 | 6.17 | |
0.3120 | 0.2791 | 10.54 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.Conclusion:
Fluosolv CX and FluoSolv NC were most effective in removing the Momentive grease.