Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate the efficiency that various cleaning methods can remove Momentive Grease from Stainless Steel substrate
Date Run:
03/15/2016Experiment Procedure:
Stainless steel coupons were selected and arranged into rows of 3 coupons, a row per cleaner. Initial weights were taken, and coupons were soiled and reweighed. The lower third of the coupons were soiled with the momentive grease. Beakers with drop in solvent replacement solutions were set up on stirring plates equipped with a stir bar. The coupons were immersed for 5 minutes. Observations were taken during the cleaning process. The coupons were dried on a rack for 15 minutes. Final weights were recorded.
Trial Results:
Cleaner | Initial wt | Final wt | % Removal |
FluoSolv CX | 0.3765 | 0.2448 | 34.98 |
0.2878 | 0.1626 | 43.50 | |
0.3062 | 0.2073 | 32.30 | |
FluoSolv NC | 0.4160 | 0.3347 | 19.54 |
0.4833 | 0.3677 | 23.92 | |
0.3835 | 0.2707 | 29.41 | |
Solstice PF | 0.3008 | 0.2042 | 32.11 |
0.7799 | 0.6668 | 14.50 | |
0.2201 | 0.1378 | 37.39 | |
Solstice PF-2A | 0.3417 | 0.2101 | 38.51 |
0.3014 | 0.1872 | 37.89 | |
0.3670 | 0.2623 | 28.53 | |
FluoSolv CX-500 | 0.1551 | 0.1446 | 6.77 |
0.1809 | 0.1704 | 5.80 | |
0.1880 | 0.1777 | 5.48 | |
Vertrel Sion | 0.3530 | 0.1317 | 62.69 |
0.4428 | 0.2205 | 50.20 | |
0.2691 | 0.1014 | 62.32 | |
FluoSolv FR-110 | 0.2046 | 0.1962 | 4.11 |
0.1997 | 0.1912 | 4.26 | |
0.1311 | 0.1249 | 4.73 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.Conclusion:
The Vertrel Sion was effective in the removal of the Momentive grease.