Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate the efficiency that various cleaning methods can remove Momentive Grease from Brass coupons\substrate.
Date Run:
03/20/2016Experiment Procedure:
Brass coupons were selected and arranged into rows of 3 coupons, a row per cleaner. Initial weights were taken, and coupons were soiled and reweighed. The lower third of the coupons were soiled. Beakers with drop in solvent replacement solutions were set up on stirring plates equipped with a stir bar. The coupons were immersed for 5 minutes. Observations were taken during the cleaning process. The coupons were dried on a rack for 15 minutes. Final weights were recorded.
Trial Results:
Cleaner | Initial wt of cont. | Final wt of cont. | %Cont Removed |
FluoSolv CX | 0.2139 | 0.0052 | 97.57 |
0.0814 | 0.0004 | 99.51 | |
0.1651 | 0.0163 | 90.13 | |
FluoSolv NC | 0.1846 | 0.0027 | 98.54 |
0.1267 | 0.0055 | 95.66 | |
0.1342 | 0.0054 | 95.98 | |
Honeywell PF | 0.1894 | 0.0004 | 99.79 |
0.1947 | 0.0008 | 99.59 | |
0.1950 | 0.0025 | 98.72 | |
Honeywell PF 2A | 0.1246 | 0.0019 | 98.48 |
0.1420 | 0.0002 | 99.86 | |
0.1483 | 0.0009 | 99.39 | |
Vertrel Sion | 0.1245 | 0.0193 | 84.5 |
0.1907 | 0.0668 | 64.97 | |
0.1074 | 0.0187 | 82.59 | |
Fluosolv CX-500 | 0.1956 | 0.1840 | 5.93 |
0.1601 | 0.1502 | 6.18 | |
0.1509 | 0.1407 | 6.76 | |
Fluosolv FR-110 | 0.1616 | 0.1554 | 3.84 |
0.2280 | 0.2184 | 4.21 | |
0.1711 | 0.1631 | 4.68 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.Conclusion:
Based on the lab results, Fluosolv CX, Fluosolv NC, Solstice PF, and Solstice PF-2A were effective in removing the Momentive grease.