Trial Purpose:
To evaluate the efficiency of various heated drop in solvent replacement in removing Momentive Grease from Aluminum.
Date Run:
03/25/2016Experiment Procedure:
Aluminum coupons were weighed to get their initial weights. The bottom third of each coupon was coated in the Momentive Grease. The coupons were re- weighed. The weights were recorded. The coupons were placed in the heated drop-in solvent replacement for 5 minutes. The coupons were removed out of the cleaning solution and placed to dry on a rack for 15 minutes. Then the final weights were taken and recorded.
Trial Results:
Cleaner | Initial wt of cont. | Final wt of cont. | %Cont Removed |
Ethyl 408 | 0.1490 | 0.1665 | -11.74 |
0.1595 | 0.1753 | -9.91 | |
0.1337 | 0.1378 | -3.07 | |
Methyl 408 | 0.1282 | 0.1387 | -8.19 |
0.1091 | 0.1119 | -2.57 | |
0.0993 | 0.1035 | -4.23 | |
FluoSolv CX | 0.1183 | 0.0445 | 62.38 |
0.1281 | 0.0573 | 55.27 | |
0.1269 | 0.0048 | 96.22 | |
FluoSolv NC | 0.1303 | 0.0666 | 48.89 |
0.1399 | 0.0716 | 48.82 | |
0.1249 | 0.0545 | 56.37 | |
Honeywell PF | 0.1427 | 0.0751 | 47.37 |
0.1137 | 0.0479 | 57.87 | |
0.1001 | 0.0520 | 48.05 | |
Honeywell PF 2A | 0.1303 | 0.0614 | 52.88 |
0.1196 | 0.0615 | 48.58 | |
0.1361 | 0.0677 | 50.26 | |
Vertrel Sion | 0.2378 | 0.0371 | 84.40 |
0.1646 | 0.0523 | 68.23 | |
0.2267 | 0.0438 | 80.68 | |
Fluosolv CX-500 | 0.3763 | 0.3539 | 5.95 |
0.5120 | 0.4874 | 4.80 | |
0.5286 | 0.5069 | 4.11 | |
Fluosolv FR-110 | 0.3497 | 0.3335 | 4.63 |
0.3472 | 0.3287 | 5.33 | |
0.3840 | 0.3653 | 4.87 |
Success Rating:
Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.