Browse past lab clients by general industry sectors
Trial Purpose:
To conduct testing on possible drop in solvents for cleaning of the Dow Corning Vacuum grease.
Date Run:
03/28/2016Experiment Procedure:
Brass coupons were arranged into rows of 3. Once the initial weights were taken, the lower third of the coupons were soiled. The coupons were places into the solvent drop in replacement solutions. Observations were taken during the process. The coupons were immersed for 5 minutes and removed to air dry on a drying rack for 15 minutes. Final weights were recorded once the coupons were dried.
Trial Results:
Cleaner | Initial wt. | Final wt. | %Cont Removed |
Vertrel Sion | 0.4790 | 0.3457 | 27.83 |
0.4023 | 0.2601 | 35.35 | |
0.4640 | 0.3345 | 27.91 | |
Fluosolv FR-110 | 0.5254 | 0.5131 | 2.34 |
0.4787 | 0.4662 | 2.61 | |
0.5132 | 0.5019 | 2.20 | |
Fluosolv CX-500 | 0.3918 | 0.3662 | 6.53 |
0.5192 | 0.4965 | 4.37 | |
0.4693 | 0.4527 | 3.54 |
Success Rating:
Test incomplete or inconclusive.