Browse past lab clients by general industry sectors
Trial Purpose:
To evaluate effectiveness of the provided cleaner in regards to removing synthetic blood from stainless steel.
Date Run:
01/03/2019Experiment Procedure:
Three pre-weighted stainless-steel coupons were soiled with synthetic blood using a swab and allowed to air dry at room temperature for 24 hours before recording the dirty weights. The coupons were immersed in a beaker with the cleaner for two minutes. Coupons were rinsed in a de-ionized water bath for one minute and dried for 24 hours before recording clean weights.
Trial Results:
| Cleaner | Initial Wt. | Final Wt. | % Removal | Average |
| BioGone RTU | 0.0010 | 0.0006 | 40.00 | 47.78 |
| 0.0016 | 0.0008 | 50.00 | ||
| 0.0015 | 0.0007 | 53.33 |
Success Rating:
A cleanliness study, addressing only various analytical techniques.Conclusion:
BioGone RTU was not considered effective in removing synthetic blood from stainless steel.