Trial Purpose:
To test previously tested cleaning chemistries on second contaminant oil.
Date Run:
09/11/1998Experiment Procedure:
Six preweighed coupons were contaminated with oil using a hand held swab and then weighed. Two cleaning solutions were made into 15% solutions using DI water in a 600 mL beaker. The solutions were heated to 130 F on a hot plate. The beakers were then placed into a Crest 40 kHz ultrasonic tank model 4Ht 1014-6 also at 130 F. Three coupons were placed in each cleaner for a set cleaning time. The cleaning time was 5 minutes. Coupons were rinsed in tap water at 120 F for 30 seconds and air dried. Final weights were taken after drying was complete.
SUBSTRATE MATERIAL: Copper/Nickel 70/30
CONTAMINANTS: Oil- Indopol L-14 (Polybutene/butene copolymer CAS# 9003-29-6)
Trial Results:
The WR Grace had limited success in removing the oil after 5 minutes of cleaning in the ultrasonic tank. Calgon AK 6215 worked exceptionally well during the cleaning period. Table 1 lists the cleaning results from this trial.
Table 1. Cleaning Efficiencies
Daraclean | Ak-6215 |
5min | 5min |
60.21 | 94.65 |
76.39 | 97.12 |
90.22 | 100.4 |
75.61 | 97.39 |
15.02 | 2.884 |
Success Rating:
A follow up test, usually based on company input.Conclusion:
Calgon’s Ak-6215 removed almost all of the contaminant after 5 minutes of cleaning. MSDSs of both chemistries have been included with this report.